Our explosion-proof heaters type FE2 are CE marked and certified to ATEX Directive 94/9/EC. They are specially designed for use in industrial applications and in dry areas where flammable substances are present such as oil refineries, petrochemical plants, timber industry, storage of hazardous waste, sewage or wastewater treatment plants, etc, where flammable substances are present in the form of air, gases or other substances.
Specifications
Test | ATEX approved (Directive 94/9/EC) |
Hazardous area classification | CE DEMKO 10 ATEX 0910365X Ex II 2 G Ex d IIB T3 Gb |
Including | NEMA Type 7 & 9. For dry indoor use. Only Do not immerse the heater in water. Turn off or not use the heater in places where it is exposed to rain or snow. |
Engine Type | Explosion-proof. Thermally protected. Permanently lubricated ball bearings. 1425 RPM (50 Hz) or 1725 rpm (60Hz) |
Fan | Aluminum sheet. Spin and steel core with 5/8 “(15.875 mm) hole. |
Blower protection | Two-piece design by late lowly. |
Mounting holes | Four 16 mm diameter holes at the top of the heater. |
Heaters | Three pieces with a long life, low watt load, with high quality metal sheathed elements. |
Temperature protection |
Automatic reset type, snap-action bimetal, open exceeded maximum allowable temperature. Nominal 100,000 switching operations at a current of 10 A. Switching current: 0.13 A. |
Control current | 115 volts, 0,130 amps, 15VA (Ground) |
Optional built-in thermostat | Explosion-proof. 2 ° C to 28 ° C. |
Control current transformer | Suitable for various input voltages, secondary 115 Volt, 25 VA. |
Contactor |
60 or 80A. Conforms to at least one million switching operations. 120 Volt, 15 VA coil (separate fuse protection). |
Heat transfer fluid | Ethylene glycol and water with a long lifetime, a freeze protection down to -45 ° |
Housing material | 1.90 mm steel. Epoxy coated with 5 phases of existing treatments, including iron phosphate. |
Core | Steel with integrated aluminum ribs, vacuum filled and hermetically sealed. |
Conduit | Heavy duty housing with large wall thickness, 3.1 mm steel |
Overpressure protection | Setting: 690 psi, pressure reduction via trickle down through the pressure relief valve, aluminum housing, replaceable only by the manufacturer. |
Operating temp. reach | -20 ° C to 40 ° C. |
Storage constraints | -45 ° C to 80 ° C, a short time to 120 ° C. Do not immerse the heater in water. Turn off or not use the heater in places where it is exposed to rain or snow. |
Execution
All FE2 heaters are equipped with VacuCore ® Liquid-to-air heat exchanger. The sucked air in the sealed core provides greater efficiency, faster warm-up and distribution of heat across the front of the heat exchanger. If necessary, the entire work can safely and easily be replaced by a new unit or conditioned. The inside of the heater is mounted in a rugged, epoxy coated, 14 mm thick casing in which the motor and fan assembly. The adjustable slats ensure the control of the air flow direction. A two-piece protective grid with small opening provides protection for all moving parts to the rear. All clips are galvanized to prevent corrosion. All aspects and details of the FE2 during the design and development subject to intensive technical analysis and testing. , And are manufactured on the basis of a registered quality assurance program. As a result, the heaters have their safety and reliability amply demonstrated.
The FE2 heaters can be hung in various ways. For this purpose, various brackets available.
Versions of this product
Type | Voltage | Power | Phase | Current |
Temperature increase |
Article number |
FE2-220150-025 | 220 Volt | 2.5 kW | 1 | 11.4 A | 5.7 °C | D220 152 025 |
FE2-220150-042 | 220 Volt | 4.2 kW | 1 | 19.1 A | 18.5 °C | D220 152 042 |
FE2-220150-063 | 220 Volt | 6.3 kW | 1 | 28.6 A | 15.8 °C | D220 152 063 |
FE2-220150-084 | 220 Volt | 8.4 kW | 1 | 38.2 A | 21.1 °C | D220 152 084 |
FE2-220150-126 | 220 Volt | 12.6 kW | 1 | 57.3 A | 15.3 °C | D220 152 126 |
FE2-230150-028 | 230 Volt | 2.8 kW | 1 | 12.0 A | 12.3 °C | D230 152 028 |
FE2-230150-046 | 230 Volt | 4.6 kW | 1 | 20.0 A | 20.2 °C | D230 152 046 |
FE2-230150-069 | 230 Volt | 6.9 kW | 1 | 29.9 A | 17.3 °C | D230 152 069 |
FE2-230150-138 | 230 Volt | 13.8 kW | 1 | 59.9 A | 16.7 °C | D230 152 138 |
FE2-240150-030 | 240 Volt | 3.0 kW | 1 | 12.4 A | 13.2 °C | D240 152 030 |
FE2-240150-050 | 240 Volt | 5.0 kW | 1 | 20.8 A | 22.0 °C | D240 152 050 |
FE2-240150-075 | 240 Volt | 7.5 kW | 1 | 31.2 A | 18.8 °C | D240 152 075 |
FE2-240150-100 | 240 Volt | 10.0 kW | 1 | 41.7 A | 25.1 °C | D240 152 100 |
FE2-240150-150 | 240 Volt | 15.0 kW | 1 | 62.5 A | 18.2 °C | D240 152 150 |
FE2-380350-025 | 380 Volt | 2.5 kW | 3 | 3.8 A | 11.0 °C | D380 352 025 |
FE2-380350-042 | 380 Volt | 4.2 kW | 3 | 6.4 A | 18.5 °C | D380 352 042 |
FE2-380350-063 | 380 Volt | 6.3 kW | 3 | 9.6 A | 15.8 °C | D380 352 063 |
FE2-380350-084 | 380 Volt | 8.4 kW | 3 | 12.8 A | 21.1 °C | D380 352 084 |
FE2-380350-125 | 380 Volt | 12.5 kW | 3 | 19.0 A | 15.1 °C | D380 352 125 |
FE2-380350-167 | 380 Volt | 16.7 kW | 3 | 25.4 A | 20.2 °C | D380 352 167 |
FE2-380350-209 | 380 Volt | 20.9 kW | 3 | 31.8 A | 12.2 °C | D380 352 209 |
FE2-400350-028 | 400 Volt | 2.8 kW | 3 | 4.1 A | 23.3 °C | D400 352 028 |
FE2-400350-046 | 400 Volt | 4.6 kW | 3 | 6.6 A | 20.2 °C | D400 352 046 |
FE2-400350-069 | 400 Volt | 6.9 kW | 3 | 10.0 A | 17.3 °C | D400 352 069 |
FE2-400350-093 | 400 Volt | 9.3 kW | 3 | 13.4 A | 23.3 °C | D400 352 093 |
FE2-400350-139 | 400 Volt | 13.9 kW | 3 | 20.1 A | 16.8 °C | D400 352 139 |
FE2-400350-185 | 400 Volt | 18.5 kW | 3 | 26.7 A | 22.4 °C | D400 352 185 |
FE2-400350-231 | 400 Volt | 23.1 kW | 3 | 33.3 A | 13.5 °C | D400 352 231 |
FE2-415350-037 | 415 Volt | 3.7 kW | 3 | 5.1 Å | 29.3 °C | D415 352 037 |
FE2-415350-075 | 415 Volt | 7.5 kW | 3 | 10.4 A | 18.8 °C | D415 352 075 |
FE2-415350-149 | 415 Volt | 14.9 kW | 3 | 20.7 A | 18.1 °C | D415 352 149 |
FE2-415350-224 | 415 Volt | 22.4 kW | 3 | 31.2 A | 13.1 °C | D415 352 224 |
FE2-440350-042 | 440 Volt | 4.2 kW | 3 | 5.5 A | 18.5 °C | D415 352 042 |
FE2-440350-084 | 440 Volt | 8.4 kW | 3 | 11.0 A | 21.1 °C | D415 352 084 |
FE2-440350-168 | 440 Volt | 16.8 kW | 3 | 22.0 A | 20.4 °C | D415 352 168 |
FE2-440350-210 | 440 Volt | 21.0 kW | 3 | 27.6 A | 12.3 °C | D415 352 210 |
Downloads
Brochure Explosion-Proof Fan Heater type FE2 |